| Sign In | Join Free | My bjjsgy.com |
|
Brand Name : Fanke High-Voltage
Model Number : FKJB
Certification : ISO9001
Place of Origin : China
MOQ : One unit
Price : Negotiable
Payment Terms : T/T
Supply Ability : 10units/month
Delivery Time : 15-20work days
Packaging Details : Export standard wooden case with fumigation free
Usage : All knids of Relays calibration testing
Output : 4U3I channels output
Current source : 3*30A
Voltage source : 4*120V
Test Accuracy : no less than 0.2%
Output frequency : 0~1000Hz
Protection Relay Test Set , 4U3I Relay Analyzer , Relay Calibration Tester , Relay Protector Comprehensive Tester
I. Technical Description
II. Function and features
III. Technical index:
1.AC current source
| Max.current output | 3×30A/phase | Resolution | 1 mA |
| 90A/ 3-ph in parallel | Voltage rise and fall time | ≤200µS | |
| Max. power output |
450 VA/phase, 900 VA/3-ph in parallel |
Amplitude-frequency characteristic |
Amplitude of variation ≤±0.5% within 25~1000 Hz |
| Output current, amplitude, frequency, and phase of each phase | Adjustable independently | Time of output |
Continuous output within 0~10A; Continuous time is more than 60S within 10A~20A; Continuous time is more than 10S within >20A |
| Output accuracy | ±0.2%±0.02% of full range within 0.2A~30A |
2.AC voltage source
| Max. voltage output | 4×120V/phase | Resolution | 1 mV |
| Max. power of output voltage | 60 VA/phase | Voltage rise and fall time | ≤120µS |
| Output amplitude, frequency, and phase of each phase | Adjustable independently | Amplitude-frequency characteristic | Amplitude of variation≤±0.5% within 25~1000 Hz |
| Output accuracy |
±0.1%±0.02% Of full range within 2~120V |
||
3.DC voltage source
| Voltage output | 0~300V(±150V) | Resolution | 1 mV |
| Accuracy | 0.5% | Max. power output | 100 VA |
4.Auxiliary DC source
| Voltage range | 110V or 80%~100% of 220V | 110V or 220V adjustable DC power output |
| Max. power output | 100 VA |
5.Phase angle
| Range | 0°~360° | Resolution | 1° |
| Accuracy | ±1° |
6.Frequency
| Range | 25~1000 Hz | Synchronism | ≤10μS |
| Accuracy |
At 25~65 Hz, absolute deviation≤0.001 Hz; At 65~450 Hz, absolute deviation≤0.01 Hz; At 450~1000 Hz, absolute deviation≤0.1 Hz |
Superposition any harmonic from two to nine. | |
7.Input
| Input impedance | ≥10KΩ | Timing precision | ≤1 mS when less than 1S |
| Resolution | 0.1 mS | Connection point |
When input voltage is within 0~±5V, it is shorted; When input voltage is within +15V~+250V or -15V~-250V, the idle contact is open. |
| 8-independent switch contact input | |||
8.GPS trigger
| Capacitance |
250V DC,0.5A; 250V AC,0.5A |
GPS trigger | error:≤50μS |
| 4 pairs of programmable switching contact output | |||
9.Power source
| AC voltage input |
Rated value: 220V-20%~+15%; Reference value: 220V±2% |
AC power frequency |
Rated value: 50 Hz-4%~+2%; Reference value: 50 Hz±1% |
| Input power |
≤1000 VA;(≥10S) ≤2000 VA : for short time |
10.Dimensions and using conditions
| Dimensions |
390×190×360 (W×H×D;mm) |
Using conditions |
T:-5~+45℃ RH:≤90% Atmospheric pressure:80~110 kPa |
| Weight | About 19 kg |
V.Working conditions
|
|
4U3I Channels Output Relay Test Set / Relay Test Kit High Accuracy 0~1000Hz Images |